Input specifications
Describe the power the charger expects from the grid.
- Voltage min (V)
- 220
- Voltage max (V)
- 230
- Frequency (Hz)
- 50
- Phases
- 3
- Power (kW)
- N/A
- Current THD
- < 5 % @ 50% ~ 100% load output
- Power factor
- > 0.98 @ 50% ~ 100% load output
- Standby power
- < 20 W
- AC Power Rating
- 496 A, 344 kVA @400V
UI & controls
User interaction and authentication capabilities.
- Dedicated display
- Yes
- Push buttons
- Yes
- Requires authentication
- Yes
- Auth methods (comma separated)
- RFID, QR Code, PnC (Plug & Charge)
- Energy Metering
- Energy Metering 3 phase AC (Input) meter & DC (Output) meter
- Load management
- Charging current configurable
- Visual Indication (LED)
- State of Ready, Charging and Fault
Protection
Ingress, cooling, and safety protections.
- IP rating
- IP55
- Cooling type
- Natural Cooling
- Overheating protection
- No
- Earth leakage protection
- No
- Safety
- IEC 61851
- Over Current
- DC output : > 300 A
- Over Voltage
- AC Input : > 470 Vac phase to phase
- Under Voltage
- AC Input : < 310 Vac phase to phase
- Over Temperature
- de-rated above 50° C
- Surge Protection
- Integrated
- DC insulation monitoring
- Integrated
- Voltage monitoring device
- Integrated
- Residual Current Leakage Breaking
- 30 mA
Communication
Connectivity options and supported protocols.
- GSM
- Yes
- LAN
- No
- Wi-Fi
- Yes
- Ethernet
- Yes
- Supported protocols
- OCPP_1_6, OCPP_2_0_1
- Vehicle protocols
- N/A
- CMS protocol details (JSON)
- N/A
- Charger Configuration
- Mobile app via Blue tooth
- Vehicle Communication
- DIN 70121, ISO 15118